This adapter uses Sentry libraries to automatically report exceptions and code errors to the developers.
For more details and for information how to disable the error reporting see Sentry-Plugin Documentation!\
Read and write register data from Huawei SUN2000 inverter and LUNA2000 battery using Modbus TCP. Third-party devices can access via the modbus proxy. Even a Huawei SmartLogger or an Huawei Emma can be integrated.
Feel free to follow the discussions in the german iobroker forum
- Node.js 20 or higher
- ioBroker host (js-controller) 6.0.11 or higher
- ioBroker admin 7.6.20 or higher
See the documentation page or browse in the wiki
- HUAWEI Inverter SUN2000 Serie (M0,M1,M2 and higher)
- HUAWEI Smart Dongle-WLAN-FE / min. Softwareversion: V100R001C00SPC133 (SDongleA-05)
- HUAWEI Luna2000 Battery
- HUAWEI Smart Power Sensor DTSU666-H or DDSU666-H
- HUAWEI Smart Logger / min. Softwareversion: V300R023C10SPC311
- HUAWEI EMMA / min. Softwareversion: V100R024C00SPC101
- Maximum
5 inverters(master/slave) can be processed, each with a battery module. Real-timevalues such as input power, output power, charging/discharging power and the grid consumption are read out at a fixed interval.- States are only written for changed data from the inverter. This relieves the burden on the iobroker instance.
- The states “inputPower” or “activePower” in the “collected” path can be monitored with a “was updated” trigger element. Because these states are always written within the set interval.
Battery charge control: The battery charging mode of Huawei LUNA2000 batteries can be controlled. Here you can activate and deactivate the battery charging mode to "charging from grid”. In addition, the charging capacity and charging power can be adjusted.Force charge discharge battery: Forced charge/discharge is usually used to test the battery connected to an inverter. Normally it is not recommended to perform forced charging/discharging.Export Control: The excess PV energy is fed into the power grid, but not all countries allow users to sell electricity. Some countries have introduced regulations to restrict the sale of electricity to the grid.modbus-proxy: Third party device such as wallbox, energy manager etc. can receive data even if the modbus interface of inverter is already in use. In addition you can mirror the sun2000 data to another IoBroker instance.- Huawei
SmartLoggerintegration: Monitors and manages the PV power system. The adapter saves the collected data in the same way as it does when read out the inverter directly. - Huawei
Emmaintegration: The Modbus access, network connectivity (WiFi and Ethernet) and the DDSU/DTSU-666H smart meter functions are integrated in one unit - the use of the Sdongle becomes redundant. In addition Huawei EV chargers and load shedding/control (via selected Shelly devices) are supported and "intelligent" controlled. - Huawei
Chargervia Emma integration: The chargers are automatically recognized and the data is saved in their own path. Statistics: Aggregates historical collected datapoints into time-based summaries (e.g. hourly, daily, monthly, yearly). These statistics should be able to be visualized in ioBroker VIS using the flexcharts adapter to create interactive diagrams for inverter performance and energy production.Surplus Power ControlThe sun2000 adapter calculates how much of your self-generated solar energy is available to power devices in your home — instead of sending it to the grid.
- statistics: new state
statistics.jsonToday— live summary of today's energy values - statistics: default chart shows energy flows above/below zero line, SOC (hourly only), self-sufficiency and self-consumption on second Y-axis
- statistics: computed values
selfSufficiencyandselfConsumptioncalculated automatically in all time-series states - statistics: data placeholders (
%%solarYield%%,%%selfSufficiency%%etc.) and negated variants (%%gridExportNeg%%etc.) for mirrored chart layouts
- fix test-and-release: deploy with 24.x
- statistics: flexcharts integration — built-in Apache ECharts configuration with bar and line chart support
- statistics: day-break visualization with alternating shaded areas for hourly charts
- statistics: per chart-type templates (
statistics.flexCharts.template.hourlyetc.) for full ECharts customization including functions - statistics: data placeholders (
%%solarYield%%,%%gridExport%%etc.) allow complete chart layout control via template states - statistics: chart output states (
statistics.flexCharts.jsonOutput.hourlyetc.) updated automatically each hour
- fix: the order of bit assignment corrected of alarmsJSON
- new state
inverter.x.emma.activeAlarmSNandinverter.x.emma.HistoricalAlarmSN: emma alarms #226 - statistics: Aggregates historical collected datapoints into time-based summaries (e.g. hourly, daily, monthly, yearly). The data is stored in the path
statisticsas JSON.
- deleted deprecated state
collected.usableSurplusPower
- dependency and configuration updates
- new state
inverter.x.derived.alarmsJSON: json array with intverter alarms (id, name, level) #226 - add ChargeDischargePower for Battery units #234
- add minimum and maximum temperature for battery packs #236
MIT License
Copyright (c) 2025-2026 bolliy stephan@mante.info
Permission is hereby granted, free of charge, to any person obtaining a copy of this software and associated documentation files (the "Software"), to deal in the Software without restriction, including without limitation the rights to use, copy, modify, merge, publish, distribute, sublicense, and/or sell copies of the Software, and to permit persons to whom the Software is furnished to do so, subject to the following conditions:
The above copyright notice and this permission notice shall be included in all copies or substantial portions of the Software.
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE SOFTWARE.